TY - JOUR
T1 - A compilation of new and published major and trace element data for NIST SRM 610 and NIST SRM 612 glass reference materials
AU - Pearce, N. J. G.
AU - Perkins, W. T.
AU - Westgate, John A.
AU - Gorton, Michael P.
AU - Jackson, Simon E.
AU - Neal, Clive R.
AU - Chenery, Simon P.
PY - 1997/6
Y1 - 1997/6
N2 - Microanalytical trace element techniques (such as ion probe or laser ablation ICP-MS) are hampered by a lack of well characterized/ homogeneous standards. Two silicate glass reference materials produced by National Institute of Standards and Technology (NIST), MIST SRM 610 and NIST SRM 612, have been shown to be homogeneous and are spiked with up to sixty one trace elements at nominal concentrations of 500 μg g
-1 and 50 μg g
-1 respectively. These samples (supplied as 3 mm wafers) are equivalent to NIST SRM 611 and NIST SRM 613 respectively (which are supplied as 1 mm wafers) and are becoming more widely used as potential microanalytical reference materials. NIST however, only certifies up to eight elements in these glasses. Here we have compiled concentration data from approximately sixty published works for both glasses, and have produced new analyses from our laboratories. Compilations are presented for the matrix composition of these glasses and for fifty eight trace elements. The trace element data includes all available new and published data, and summaries present the overall average and standard deviation, the range, median, geometric mean and a preferred average (which excludes all data outside ± one standard deviation of the overall average). For the elements which have been certified, there is a good agreement between the compiled averages and the NIST data. This compilation is designed to provide useful new working values for these reference materials.
AB - Microanalytical trace element techniques (such as ion probe or laser ablation ICP-MS) are hampered by a lack of well characterized/ homogeneous standards. Two silicate glass reference materials produced by National Institute of Standards and Technology (NIST), MIST SRM 610 and NIST SRM 612, have been shown to be homogeneous and are spiked with up to sixty one trace elements at nominal concentrations of 500 μg g
-1 and 50 μg g
-1 respectively. These samples (supplied as 3 mm wafers) are equivalent to NIST SRM 611 and NIST SRM 613 respectively (which are supplied as 1 mm wafers) and are becoming more widely used as potential microanalytical reference materials. NIST however, only certifies up to eight elements in these glasses. Here we have compiled concentration data from approximately sixty published works for both glasses, and have produced new analyses from our laboratories. Compilations are presented for the matrix composition of these glasses and for fifty eight trace elements. The trace element data includes all available new and published data, and summaries present the overall average and standard deviation, the range, median, geometric mean and a preferred average (which excludes all data outside ± one standard deviation of the overall average). For the elements which have been certified, there is a good agreement between the compiled averages and the NIST data. This compilation is designed to provide useful new working values for these reference materials.
KW - INDUCTIVELY-COUPLED PLASMA
KW - RARE-EARTH ELEMENTS
KW - ATOMIC-ABSORPTION SPECTROMETRY
KW - GAMMA-RAY SPECTROMETRY
KW - GEOCHEMICAL REFERENCE MATERIALS
KW - LASER-ABLATION MICROPROBE
KW - LOW FLUX REACTOR
KW - MASS-SPECTROMETRY
KW - ICP-MS
KW - GEOLOGICAL-MATERIALS
UR - http://www.scopus.com/inward/record.url?scp=33745153464&partnerID=8YFLogxK
U2 - 10.1111/j.1751-908X.1997.tb00538.x
DO - 10.1111/j.1751-908X.1997.tb00538.x
M3 - Article
SN - 0150-5505
VL - 21
SP - 115
EP - 144
JO - Geostandards Newsletter
JF - Geostandards Newsletter
IS - 1
ER -